New Millennium Building Systems

Certifications

New Millennium is a Steel Joist Institute (SJI) member company, fully certified to manufacture K, LH and DLH-Series Steel Joists, and Joist Girders. New Millennium is also a Steel Deck Institute (SDI) member company, fully certified to manufacture roof deck, form deck, and composite floor deck

ICC Reports

ESR-3818

This report covers all New Millennium facilities that produce roof deck (types RD, F, B, BI, and N), form deck (types FD, FDR, and FDI), and composite deck panels (types CD and CDI)

ESR-2657

This report covers New Millennium steel roof panels: D4.5, D6 and D7.5 Deep-Dek® D4.5A, D6A and D7.5A Deep-Dek® Acoustical; D4.5C, D6C and D7.5C Deep-Dek® Cellular; D4.5CA, D6CA and D7.5CA Deep-Dek® Cellular Acoustical; Versa-Dek® Roof Deck Panels; and Versa-Dek® Acoustical Roof Deck Panels

ESR-2635

This report covers New Millennium composite deck panels: Versa-Dek® Composite 3.5 LS Deck Panels, and Versa-Dek® Composite 3.5 LS Acoustical Deck Panels

ESR-2839

This report covers New Millennium composite floor deck panels: Deep-Dek® Composite 4.5 and 6; Deep-Dek® Composite 4.5 and 6 Cellular; and Deep-Dek® Composite 4.5 and 6 Cellular Acoustical Floor Deck Panels

ESR-3477

This report covers New Millennium Versa-Wedge® Steel Deck Hangers

ESR-1169

This report covers New Millennium Steel Floor and Roof Deck Panels

  • New Millennium products meet FM, UL and ULC requirements
  • The Indiana, Virginia, FLorida, Tennessee, Arkansas, and Arizona facilities are ICC certified
  • F, B and N deck are Factory Mutual approved for use as a component in Class 1-60, 1-75, & 1-90 wind uplift metal roof decking construction
  • Steel deck products are approved by Underwriters Laboratory and listed in the UL Fire Resistance Directory
  • All acoustical deck has been tested in accordance with ANSI ASTM C423 & E795 to determine the noise reduction coefficient (NRC) rating
  • Welders are certified in accordance with AWS D1.1 and D1.3
  • The Indiana, Virginia and Nevada facilities meet CSA Standard W47.1 in Division 2 for open web joist
  • The Indiana facility is certified in accordance with the requirements of the current IBC/Michigan Building Code, Chapter 17, Section 1705, Paragraph 2.2
  • The Florida facility is certified in accordance with the requirements of the Miami-Dade County, Florida Building Code, Article IV, Chapter 8
  • The Arkansas and Florida facilities are certified in accordance with the Houston, Texas Building Code, section 1704.2.2
  • The Nevada and Mexico facilities are certified in accordance with the requirements of LA City
  • The Nevada facility is certified in accordance with the requirements of Clark County