New Millennium products are engineered and manufactured to exacting quality standards—both internally and externally. We are a Steel Joist Institute member company, fully certified to manufacture K-, LH- and DLH-Series steel joists and joist girders. New Millennium is also a Steel Deck Institute member company, fully certified to manufacture roof deck, form deck and composite floor deck.
ICC Certified
ESR-1169
This report covers New Millennium steel roof and floor deck panels made at the Memphis, TN facility, including B-Dek, N-Dek, NW32®, Composite Floor-Dek, and Form Deck (cellular versions included where applicable).
ESR-2635*
This report covers Versa-Dek® 2.0 S Composite, Versa-Dek® 2.0 LS Composite, Versa-Dek® 2.0 S ES Composite, Versa-Dek® 2.0 LS ES Composite, Versa-Dek® 3.5 LS Composite and Versa-Dek® 3.5 LS Composite Acoustical Deck Panels.
ESR-2657*
This report covers New Millennium steel roof panels: D4.5, D6.0 and D7.5 Deep-Dek® D4.5A, D6.0A and D7.5A Deep-Dek® Acoustical; D4.5C, D6.0C and D7.5C Deep-Dek® Cellular; D4.5CA, D6.0CA and D7.5CA Deep-Dek® Cellular Acoustical; Versa-Dek® Roof Deck Panels; and Versa-Dek® Acoustical Roof Deck Panels.
ESR-2839*
This report covers New Millennium composite floor deck panels: Deep-Dek® Composite 4.5, 6.0 and 7.5; Deep-Dek® Composite 4.5, 6.0 and 7.5 Cellular; and Deep-Dek® Composite 4.5, 6.0 and 7.5 Cellular Acoustical Floor Deck Panels.
ESR-3376*
This report covers New Millennium WN-Series wood nailer open-web steel joists.
ESR-3477
This report covers New Millennium Versa-Wedge® Steel Deck Hangers.
ESR-3818*
This report covers all New Millennium facilities that produce roof deck (types RD, F, B, BI, and N), form deck (types FD, FDR, and FDI), and composite deck panels (types CD and CDI).
FACTORY MUTUAL APPROVED STEEL DECKS
If pursuing Factory Mutual insurance underwriting, the Building Engineer of Record (EOR) shall follow the FM design requirements and determination of approved roof assemblies. Contacting a local FM Regional Engineer will assist the EOR in determining design aspects and impact to the structural system. The following is a resource guide for typical steps and recommendations in navigating FM wind resistance ratings for the roof assembly, utilizing steel roof deck.
Step 1: Access FM’s design tools within “RoofNav” (https://roofnav.app.fmglobal.com) and determine the building ratings requirements with the Ratings Calculator to determine fire, hail, and wind uplift ratings for the building.
Step 2: The Assembly Search tool can now be utilized with the determined fire, hail, and wind ratings from Step 1. Different assemblies may be necessary for varying wind rating zones (Zone 1’, 1, 2, 3) or the worst-case wind zone. Note, there are thousands of possible assemblies, working with the Architect, Contractor, and FM Regional Engineer can assist in narrowing down the options and providing the preferred assembly.
As specified in FM Data Sheet 1-28, “The design of the supports themselves, such as girts, studs, mullions (unless part of a tested window assembly), joists, purlins and their primary supports, are not included.” Therefore, the roof joists and primary supports are not required to be designed for FM wind pressures.
Step 3: Verify and specify the FM approved steel deck and roofing attachments that meet the wind ratings for the various wind zones. For wind zones in excess of 1-90, one must select an FM Approved assembly meeting the higher wind zone requirement, and the corresponding FM approved steel deck for that assembly. FM Data Sheet 1-29 can also be accessed from FM’s website and provides further guidance as well as 1.5” B deck and 3” N deck span tables for wind load ratings in excess of 1-90.
Step 4: Determine the steel deck attachment configuration that meets the assembly requirements. Depending upon the selected FM assembly, there may or may not be a deck connection specified. If not, FM Data Sheet 1-29 provides further guidance on deck connection spacing for higher wind ratings in Zone 2 and Zone 3. In addition, fastening companies (Hilti, Pneutek, etc.) have their FM approved deck fastener documentation available through RoofNav “Product Search.”
2" Versa-Dek®
New Millennium steel roof deck type 2.0VLSES (dovetail) is approved for use as a component of Factory Mutual compliant roof systems.
2" Versa-Dek® Acoustical
New Millennium steel roof deck type 2.0VLSESA (dovetail acoustical) is approved for use as a component of Factory Mutual compliant roof systems.
3.5" Versa-Dek®
New Millennium steel roof deck type 3.5VLS (dovetail) is approved for use as a component of Factory Mutual compliant roof systems.
3.5" Versa-Dek® Acoustical
New Millennium steel roof deck type 3.5VLSA (dovetail acoustical) is approved for use as a component of Factory Mutual compliant roof systems.
Interlocking B Deck
New Millennium steel roof deck type BI (interlocking) is approved for use as a component of Factory Mutual compliant roof systems.
B Deck
New Millennium steel roof deck type B (wide rib – WR) is approved for use as a component of Factory Mutual compliant roof systems.
B-Dek Acoustical
New Millennium B-Dek Acoustical steel roof deck is approved for use as a component of Factory Mutual compliant roof systems.
NW32® Deck
New Millennium steel roof deck types NW32, NW32I, NW32A, and NW32IA (deep rib – DR) are approved for use as a component of Factory Mutual compliant roof systems.
N Deck
New Millennium steel roof deck type N (deep rib – DR) is approved for use as a component of Factory Mutual compliant roof systems.
N-Dek Cellular
New Millennium N-Dek Cellular steel roof deck is approved for use as a component of Factory Mutual compliant roof systems.
N-Dek Cellular Acoustical
New Millennium N-Dek Cellular Acoustical steel roof deck is approved for use as a component of Factory Mutual compliant roof systems.
N-Dek Acoustical
New Millennium N-Dek Acoustical steel roof deck is approved for use as a component of Factory Mutual compliant roof systems.
F Deck
New Millennium steel roof deck type F is approved for use as a component of Factory Mutual compliant roof systems.
UL CERTIFICATIONS
New Millennium deck products are approved for use in UL fire rated assemblies. Please visit UL/ULC Online Certifications Directory, UL/ULC File Numbers R20577 and R22282 (links provided below) for an up-to-date listing of UL/ULC Designs in which New Millennium deck products have been approved. UL design numbering system has been provided below for your use in navigating to the specific construction types required for your project.
NUMBERING SYSTEM FOR UL DESIGNS
Floors - Ceilings
D200-299: Concrete on steel deck w/exposed grid system
D300-399: Concrete on steel deck w/mineral or fiber board
D500-599: Concrete on steel deck w/gypsum board
D700-899: Concrete on steel deck w/spray-applied fire-resistive material
D900-999: Concrete on steel deck w/no protection
E700-899: Concrete on steel deck w/spray-applied fire-resistive material
E900-999: Concrete on steel deck w/no protection
G200-299: Concrete on steel deck & steel joists w/exposed grid system
G500-599: Concrete on steel deck & steel joists w/gypsum board
G700-899: Concrete on steel deck & steel joists w/spray-applied fire-resistive material
Type 3.5VLSC in Joint System Design No. HW-S-0127
L700-899: Wood on steel deck w/spray-applied fire-resistive material
N700-899: Concrete on steel deck & steel joists w/spray-applied fire-resistive material
Roof - Ceiling
P200-299: Steel deck w/exposed grid system
P400-499: Steel deck w/metal lath
P500-599: Steel deck w/gypsum board
P700-899: Steel deck w/spray-applied fire-resistive material
P900-999: Steel deck w/no protection
Floors - Ceilings
D900-999: Concrete on steel deck (as structural framing member) w/no protection
L500-599: Wood on steel deck (as structural framing member) w/gypsum board
Floors - Ceilings (Canada)
F700-799: Concrete on steel deck w/spray-applied fire-resistive material – cementitious
F800-899: Concrete on steel deck w/spray-applied fire-resistive material – sprayed fibre
F900-999: Concrete on steel deck w/no protection
SJI Certifications
New Millennium has five facilities approved by the Steel Joist Institute (SJI) to manufacturer steel joists in accordance with SJI standards.

SDI Certifications
New Millennium facilities that manufacture steel roof deck, floor deck, and form deck have been approved by the Steel Deck Institute (SDI).

- New Millennium products meet Factory Mutual, Underwriters Laboratory and Underwriters Laboratories of Canada requirements.
- The Indiana, Virginia, Florida, Tennessee, and Arkansas facilities are ICC-certified.
- Deck types F, B, N, NW32, and Versa-Dek 2.0 and 3.5, limited to select interlocking and acoustical variations, are FM-approved for use as components in Class 1-60, 1-75 and 1-90 wind uplift metal roof decking construction.
- Steel deck products are approved by UL and listed in the UL Fire Resistance Directory.
- All acoustical deck has been tested in accordance with ANSI ASTM C423 and E795 to determine the noise reduction coefficient rating.
- Welders are certified in accordance with AWS D1.1 and D1.3.
- The Indiana, Virginia and Nevada facilities meet CSA Standard W47.1 in Division 2 for open-web joist.
- The Florida facility has Miami-Dade County approval.
- The Arkansas and Florida facilities are certified in accordance with the Houston, Texas, Building Code, section 1704.2.2.
- The Nevada and Mexico facilities are certified in accordance with the requirements of LA City.